78 Brocade BigIron RX Series Hardware Installation Guide
53-1002483-03
Testing network connectivity
3
Table 16 defines the fields shown in the command output.
TABLE 16 Cable statistics
This line... Displays...
Port The interface that was tested.
Speed The port’s current line speed.
Local pair The local link name.
Pair Length The cable length when terminated, or the distance to the point of fault
when the line is not up.
Remote pair The remote link name.
Pair status The status of the link. This field displays one of the following:
Terminated: The link is up
Shorted: A short is detected in the cable
Open: An opening is detected in the cable
ImpedMis: The impedance is mismatched
Failed: The TDR test failed