Brocade Communications Systems S3-1002483-03 Manual de usuario Pagina 104

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 206
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 103
92 Brocade BigIron RX Series Hardware Installation Guide
53-1002483-03
Managing the interface modules
4
The <slot-number> parameter specifies the BigIron RX chassis slot number that contains the
interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1 – 8
for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from the management module’s flash memory
For example, to specify an immediate boot from the primary IronWare image in the management
module’s flash memory for the interface module installed in slot 1, enter the following command at
the Privileged EXEC level of the CLI:
BigIron RX# lp boot system mp primary 1
Syntax: lp boot system mp primary | secondary <slot-number>
The primary and secondary keywords specify the primary or secondary IronWare image in the
management module’s flash memory.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from the interface module’s flash memory
For example, to specify an immediate boot from the primary IronWare image in the interface
module’s flash memory for the interface module installed in slot 1, enter the following command at
the Privileged EXEC level of the CLI:
BigIron RX# lp boot system flash primary 1
Syntax: lp boot system flash primary | secondary <slot-number>
The primary and secondary keywords specify the primary or secondary IronWare image in the
interface module’s flash memory.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from a TFTP server
For example, to specify an immediate boot for the interface module installed in slot 1 from a TFTP
server, enter the following command at the Privileged EXEC level of the CLI:
BigIron RX# lp boot system tftp 123.123.123.123 primary 1
Syntax: lp boot system tftp <ip-address> <filename> <slot-number>
The <ip-address> parameter specifies the IP address of the TFTP server from which the interface
module will be booted.
The <filename> parameter specifies the name of the image from which to boot the interface
module.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Vista de pagina 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 205 206

Comentarios a estos manuales

Sin comentarios