Brocade Communications Systems MLX Series Guía de instalación Pagina 53

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 342
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 52
Brocade MLX Series and NetIron XMR Hardware Installation Guide 39
53-1003267-02
Router modules
1
At startup, the fans operate at high speed. After a period of time, the management module
changes the fan speed to low.
By default, the router polls the temperature sensor on each module every 60 seconds for a
temperature reading. Depending on the results, the router will:
Leave the fan speed as is
Increase the fan speed
Decrease the fan speed
Shut down a module to prevent damage
If the temperature of a module exceeds specified high temperature thresholds, the system
generates a Syslog message and SNMP trap. The system can also shut down the module if the
temperature exceeds the highest threshold.
You can change default low and high temperature thresholds for modules and fan speeds. Refer to
“Changing temperature thresholds for modules and fan speeds” on page 235.
1 - 10 Fan modules 1 - 10, numbered as labeled
Vista de pagina 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 341 342

Comentarios a estos manuales

Sin comentarios