Power supply, fan assembly, and airflow direction support
matrix
The power supply and fan assembly units are identified by the following airflow directions:
Intake FRU with an orange "I" label or without any label: Pulls air from the non-port side of the
switch and exhausts it out the port side.
These units are also identified as/by:
Port-side air exhaust
Nonport-side air intake
Back-to-front (nonport-side to port-side) airflow
Fan direction is shown as "Reverse" airflow in the
chassisShow command output
Part numbers ending with -R
Exhaust FRU with a green "E" label: Pulls air from the port side of the switch and exhausts it out
the non-port side.
These units are also identified as/by:
Port-side air intake
Nonport-side air exhaust
Front-to-back (port-side to nonport-side) airflow
Fan direction is shown as "Forward" airflow in the
chassisShow command output
Part numbers ending with -F
The AC powers supplies, fan assemblies, and airflow directions are supported as per the following
table:
Platform Shipping FRU
configuration per
chassis
Combined AC PSU and fans
Intake FRU Labeled Exhaust FRU Labeled
Brocade 5100 2 23-0000092-xx No NA -
Brocade 6505 1 23-0000092-xx No NA -
Brocade 6510 2 23-0000092-xx No 23-0000113-xx " E "
Brocade 7800 2 23-0000092-xx No NA -
Brocade VA-40FC 2 23-0000092-xx No 23-1000032-xx " E "
Brocade 6510 Hardware Installation Guide 39