Brocade Communications Systems BR-1020 Guía para resolver problemas Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 110
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
28 Brsocade Adapters Troubleshooting Guide
53-1001253-01
FCoE and Fibre Channel problems
2
FCoE and Fibre Channel problems
This section provides resolution of problems related to Fiber Channel and FCoE.
Loss of sync and loss of signal errors in port statistics
If the port is having loss of synchronization and signal errors, refer to the following descriptions of
possible causes and recommended actions to help resolve the problem. Learn more about
displaying port statistics in “Port statistics” on page 59.
Possible Cause: Possible physical link problem.
Action: Check authentication settings on the switch and adapter. For the switch, execute the
authutil --show Fabric Fabric OS command. For the adapter, execute the BCU auth --show command
(refer to Authentication settings” on page 73).
Action: Use the BCU auth --show <port> command on the adapter and Fabric OS authutil --show
command on the switch.
Action: Check the shared secret configuration on the attached switch and on the adapter. For the
switch, execute the secAuthSecret Fabric OS command. For the adapter, execute the auth –-secret
BCU command. Refer to Authentication settings” on page 73 for details on using the auth-secret
command.
Fabric authentication failures
If failures in the authentication process between the adapter in host system and the connected
switch occur, refer to the following descriptions of possible causes and recommended actions to
help resolve the problem.
Possible Cause: Authenticating configuration is incorrect.
Action: Check authentication settings on the switch and adapter. For the switch, execute the
authutil --show Fabric OS command. For the adapter, execute the BCU auth --show command (refer
to Authentication settings” on page 73).
Action: Check the shared secret configuration on the attached switch and adapter. For the switch,
execute the secAuthSecret Fabric OS command. For the adapter, execute the auth –-secret BCU
command. Refer to Authentication settings” on page 73 for details on using the auth-secret
command.
I/Os are not failing over immediately on path failure in MPIO setup
When multipath I/O (MPIO) is enabled and input/output operations are not failing over immediately
when a path failure occurs, refer to the following descriptions of possible causes and
recommended actions to help resolve the problem.
Possible Cause: Improper driver mpiomode setting.
Action: Execute the port --query <port_id> BCU command and ensure fcpim MPIO mode is enabled
(which implies zero Path TOV values) or that fcpim MPIO mode is disabled with the expected “Path
TOV” settings (default is 30 seconds).
Vista de pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 109 110

Comentarios a estos manuales

Sin comentarios