68 Brocade Adapters Troubleshooting Guide
53-1001253-01
Diagnostics
3
4. Select FC Trace Route.
5. Select the adapter port and target for which you wish to trace the route.
6. Enter a test cycle if desired.
7. Clic k Start.
Echo test
Use the BCU and HCM to initiate an echo test between the adapter port and a Fibre Channel end
point. This sends an ECHO command and response sequence between the adapter port and target
port to verify connection with the target.
Performing an echo test through BCU
Use the fcdiag --fcecho BCU command to initiate an echo test between the adapter and remote
port.
fcdiag –-fcecho <port_id> <rpwwn> [-l lpwwn]
where:
port_id ID of the port for which you want to perform the test.
rpwwn Remote port WWN to which the echo command is being sent.
lpwwn Logical port WWN. 0 indicates the base port.
Performing an echo test through HCM
Use the Echo Test feature to initiate an echo test between the adapter port and a Fibre Channel
end point:
1. Launch the HCM.
2. Select Configure > Diagnostics
3. Click the FC Protocol Tests tab.
4. Select Echo Test.
5. Select the adapter port and target port for the test.
6. Enter a test cycle if applicable.
7. Clic k Start.
SCSI test
Use the fcdiag --scsitest BCU command to test the SCSI link between the adapter and remote port.
fcdiag –-scsitest <port_id> <rpwwn> [-l lpwwn]
where:
port_id ID of the port for which you want to test the SCSI link.
rpwwn Remote port WWN connected to the adapter by the SCSI link.